Reagent i-STAT Chem8+ Renal / General Chemistry Sodium / Potassium / Chloride / Ionized Calcium / Urea Nitrogen / Glucose / Creatinine / Hematocrit / TCO2 For use with i-STAT1 System 9 Tests 25 Cartr

$418.00

Mfr# 09P31-26

Notice - This item is not returnable

  • Requires Refrigeration

  • The i-STAT CHEM8+ cartridge with the i-STAT 1 System is intended for use in arterial or venous whole blood in point of care or clinical laboratory settings

  • Each i-STAT single-use cartridge uses advanced biosensor technology that applies microfluidics to process the most comprehensive range of clinical tests in a single platform, allowing clinicians to access the time-sensitive diagnostic information they need

  • To perform a test, 2 to 3 drops of blood are applied to a cartridge, which is then inserted into the i-STAT handheld

  • Prior to running a test, each cartridge initiates a series of preset quality control diagnostics, from monitoring the quality of the sample to validating the reagent

  • Each test cartridge contains chemically sensitive biosensors on a silicon chip that are configured to perform specific tests

Mfr# 09P31-26

Notice - This item is not returnable

  • Requires Refrigeration

  • The i-STAT CHEM8+ cartridge with the i-STAT 1 System is intended for use in arterial or venous whole blood in point of care or clinical laboratory settings

  • Each i-STAT single-use cartridge uses advanced biosensor technology that applies microfluidics to process the most comprehensive range of clinical tests in a single platform, allowing clinicians to access the time-sensitive diagnostic information they need

  • To perform a test, 2 to 3 drops of blood are applied to a cartridge, which is then inserted into the i-STAT handheld

  • Prior to running a test, each cartridge initiates a series of preset quality control diagnostics, from monitoring the quality of the sample to validating the reagent

  • Each test cartridge contains chemically sensitive biosensors on a silicon chip that are configured to perform specific tests

CLIA Classification CLIA Moderate Complexity

For Use With For use with i-STAT1 System

Number of Tests 9 Tests

Product Dating: we will ship >= 30 days

Sample Type Whole Blood Sample

Storage Requirements Requires Refrigeration

Test Format Cartridge

Test Name Sodium / Potassium / Chloride / Ionized Calcium / Urea Nitrogen / Glucose / Creatinine / Hematocrit / TCO2

Test Type Renal / General Chemistry

Time to Results 2 Minute Results

UNSPSC Code 41115808

Volume 25 Cartridges