Shop › Heat and Moisture Exchanger with Filter McKesson 29.2 mg H2O / L @ VT 500 mL 2.5 cm H20 @ 30 LPM | 16-6220 Image 1 of 2 Image 2 of 2 Heat and Moisture Exchanger with Filter McKesson 29.2 mg H2O / L @ VT 500 mL 2.5 cm H20 @ 30 LPM | 16-6220 from $17.00 McKesson Mini In-Line Heat and Moisture Exchanger with CO2 Port Mini design allows tidal volumes from 150 mL - 1000 mL for broad use among children and adults In-line design allows for use with gas elbow to fit to fit user preference For short-term airway humidification For the moisture and heat retention for return to the patient and provides filtration for prevention of breathing system contamination Optimal choice for enhancing the effectiveness of any breathing systems such as ventilators or anesthesia circuits Bacterial/viral filtration efficiencies in excess of 99.9% High moisture retention characteristics Clear housing to view levels of humidification Provide superior moisture output, minimum size, low breathing resistance True hygroscopic condensing humidifier (HCH) for maximal performance without potentially harmful chemicals Treated with physiologically safe calcium chloride, hygroscopic membrane traps patient’s moisture providing effective airway humidification Low resistance to airflow minimizes work of breathing Effective filtration reduces the risk of colonization in breathing tubes and minimizes sampling line blockage End tidal CO2 sampling port offers convenient access to airway gases Luer gas sampling ports for secure connection ISO-standard connections for secure, leak-resistant attachment to breathing systems Conveniently-located luer connection permits gas sampling at the top of the housing, just as if a common gas sampling elbow were being used Disposable available in convenient case quantities and individually-wrapped for single patient use Not Made with Natural Rubber Latex 1 Per Pack, 50 Packs Per Case Qty: Select Qty 1 50 Add To Cart Added! McKesson Mini In-Line Heat and Moisture Exchanger with CO2 Port Mini design allows tidal volumes from 150 mL - 1000 mL for broad use among children and adults In-line design allows for use with gas elbow to fit to fit user preference For short-term airway humidification For the moisture and heat retention for return to the patient and provides filtration for prevention of breathing system contamination Optimal choice for enhancing the effectiveness of any breathing systems such as ventilators or anesthesia circuits Bacterial/viral filtration efficiencies in excess of 99.9% High moisture retention characteristics Clear housing to view levels of humidification Provide superior moisture output, minimum size, low breathing resistance True hygroscopic condensing humidifier (HCH) for maximal performance without potentially harmful chemicals Treated with physiologically safe calcium chloride, hygroscopic membrane traps patient’s moisture providing effective airway humidification Low resistance to airflow minimizes work of breathing Effective filtration reduces the risk of colonization in breathing tubes and minimizes sampling line blockage End tidal CO2 sampling port offers convenient access to airway gases Luer gas sampling ports for secure connection ISO-standard connections for secure, leak-resistant attachment to breathing systems Conveniently-located luer connection permits gas sampling at the top of the housing, just as if a common gas sampling elbow were being used Disposable available in convenient case quantities and individually-wrapped for single patient use Not Made with Natural Rubber Latex 1 Per Pack, 50 Packs Per Case